1.
Journal of Medical Biomechanics ; (6): E869-E876, 2021.
Article in Chinese | WPRIM | ID: wpr-920696

ABSTRACT

Objective To explore the biomechanical mechanism of aortic insufficiency (AI) after single aortic valve replacement (SAVR) in children and propose the corresponding countermeasures. Methods The idealized aortic valve model and postoperative growth model were constructed. By changing the length of leaflet free edge, leaflet height as well as improving the design with a concave structure, the effects of different structure dimensions on movement synchronization and closing performance of the aortic valve after surgery were compared. Results The closure of the replacement leaflet lagged behind the autologous leaflet, which fitted 2 mm below free edge of the replacement leaflet. AI occurred 6 years after operation. Increasing leaflet height could not improve the postoperative effect and would increase the maximum stress of the leaflet. Increasing free edge length by 10% could improve the postoperative outcomes, while increasing free edge length by 15% would cause the leaflet to be too long, hence resulting in a poor fit of the aortic valve. Compared with the traditional structure, the concave structure was more beneficial for closing performance of the aortic valve, and it could effectively reduce the maximum stress by 20% with the best effect. Conclusions The leaflet movement will be out of synchronization after SAVR, the point of convergence will be shifted, and AI will appear 6 years after surgery. It is recommended to use a concave structure with free edge length increased by 10%, while increasing leaflet height is not recommended.

2.
Journal of Biomedical Engineering ; (6): 737-744, 2019.
Article in Chinese | WPRIM | ID: wpr-774147

ABSTRACT

This study aims to explore the effect of aortic sinus diameter on aortic valve opening and closing performance in the case of no obvious disease of aortic valve and annulus and continuous dilation of aortic root. A total of 25 three-dimensional aortic root models with different aortic sinus and root diameters were constructed according to the size of clinical surgical guidance. The valve sinus diameter S is set to 32, 36, 40, 44 and 48 mm, respectively, and the aortic root diameter is set to 26, 27, 28, 29 and 30 mm, respectively. Through the structural mechanics calculation with the finite element software, the maximum stress, valve orifice area, contact force and other parameters of the model are analyzed to evaluate the valve opening and closing performance under the dilated state. The study found that aortic valve stenosis occurs when the = 32 mm, = 26, 27 mm and = 36 mm, = 26 mm. Aortic regurgitation occurs when the = 32, 36 and 40 mm, = 30 mm and = 44, 48 mm, = 29, 30 mm. The other 15 models had normal valve movement. The results showed that the size of the aortic sinus affected the opening and closing performance of the aortic valve. The smaller sinus diameter adapted with the larger root diameter and the larger sinus diameter adapted with the smaller root diameter. When the sinus diameter is 40 mm, the mechanical performance of the valve are good and it can well adapt with the relatively large range of aortic root dilation.


Subject(s)
Humans , Aorta , Aortic Valve , Physiology , Aortic Valve Insufficiency , Aortic Valve Stenosis
SELECTION OF CITATIONS
SEARCH DETAIL